Diese Seiten sind technisch und auf Englisch. Sie sammeln, was die Mitwirkenden von OpenAmpere über die Geräte herausgefunden haben, jeweils mit Quelle und wie sicher die Angabe ist. Sie zeigen den neuesten Stand der Entwicklung, der manchmal schon über deine installierte Version hinausgeht. Es sind keine offiziellen Angaben der Hersteller. Für die Einrichtung brauchst du sie nicht, die App erklärt dir alles Nötige.

FoxESS AC EV Charger

Not official manufacturer information: compiled by the OpenAmpere contributors, possibly incomplete or wrong. Changing device settings can affect warranty and grid connection rules. No affiliation with FoxESS or EKD, not legal advice. See Device knowledge.

Applies to: FoxESS AC EV Charger (wallbox, single- and three-phase models) · Sold as: "Ampere.ChargePro" (22 kW) by EKD (amperesolar.de/chargepro, documented; see names.md); owners report it with EKD (Ampere.IQ) systems (#412) · OpenAmpere: wallbox module foxess_ac, read-only wallbox check in the setup and live view (wallbox/native.py, #439), its work mode written on request (#464), its charging modes as a simulation without writing (#440) until the owner switches on real control (#465) · Support: display (live view and check) and the work mode on request (#464); control of charging as a test once the owner switches it on per wallbox (#465, offered as such in the setup since #503) · Confirmed on a real device: partly (connection and the read registers on one three-phase charger of an EKD system, #431; OpenAmpere's write of the work mode "controlled" and the fallback when the controller stops on a second one, discussion #621)

Summary

Registers

Read by the check over one connection: 0x1000–0x1021, 0x3000–0x3006 and, separately, 0x3007–0x300B (missing on single-phase models). The raw words go into the report through OpenAmpere's masking (serial-like text shortened, private words removed). Nothing is written.

Read by the live view (#439) every 10 s over one short connection, closed after reading: 0x1000–0x1015 and 0x3000–0x3006, then 0x3007–0x300B (skipped when the charger refuses it as unknown addresses, as single-phase models may). The energy counters, the card number, the model code and the serial number (0x1016–0x1031) are not read at all. Only function code 3; nothing is written.

RegisterMeaningType, scale, signR/WStatusSource
0x1000, 0x1002, 0x1004, 0x1006–0x1007, 0x100F–0x1010Read as part of the block, not interpreted by OpenAmpere–R FC03openfoxess.py
0x1001Firmware: high byte major, low byte minorU16R FC03confirmedFoxESS EV Charger Modbus TCP protocol V1.6; plausible on one device: owner's diagnostics report, #431
0x1003Status: 0 idle, 1 connected (waiting for the start command), 2 starting (waiting for the car), 3 charging, 4 paused, 5 finished, 6 fault, 8 locked (no operation possible)U16R FC03documented; 0 (idle, no car) confirmedFoxESS EV Charger Modbus TCP protocol V1.6; plausible on one device: owner's diagnostics report, #431
0x1003 = 9Status "switching phases": not in the document, seen on real devicesU16R FC03derivedowner reports in public evcc discussions
0x1005Plug connected; read 1 on one device while idle with no car plugged in, so the meaning is doubtful (not shown in the app, only in the report)U16, 0/1R FC03open (documented, contradicted on one device)FoxESS EV Charger Modbus TCP protocol V1.6; owner's diagnostics report, #431
0x1008–0x100AVoltage L1, L2, L3U16, ×0.1 VR FC03confirmedFoxESS EV Charger Modbus TCP protocol V1.6; plausible on one device: owner's diagnostics report, #431
0x100B–0x100DCurrent L1, L2, L3U16, ×0.1 AR FC03documentedFoxESS EV Charger Modbus TCP protocol V1.6
0x100ECharging powerU16, ×0.1 kWR FC03documentedFoxESS EV Charger Modbus TCP protocol V1.6
0x1011Maximum powerU16, ×0.1 kWR FC03confirmedFoxESS EV Charger Modbus TCP protocol V1.6; plausible on one device: owner's diagnostics report, #431
0x1012Minimum powerU16, ×0.1 kWR FC03confirmedFoxESS EV Charger Modbus TCP protocol V1.6; plausible on one device: owner's diagnostics report, #431
0x1013Maximum currentU16, ×0.1 AR FC03confirmedFoxESS EV Charger Modbus TCP protocol V1.6; plausible on one device: owner's diagnostics report, #431
0x1014Minimum currentU16, ×0.1 AR FC03confirmedFoxESS EV Charger Modbus TCP protocol V1.6; plausible on one device: owner's diagnostics report, #431
0x1015Alarm bits; bit 1 was set on one device while idle, meaning unknownU16, bit fieldR FC03documented; bit 1: openFoxESS EV Charger Modbus TCP protocol V1.6; owner's diagnostics report, #431
0x1016–0x1019Energy counters: 0x1016–0x1017 lifetime, 0x1018–0x1019 the current session; OpenAmpere decodes only the lifetime counter, for the "plausible" check of the reportU32, ×0.1 kWhR FC03; removed from the report, only "plausible" yes/nodocumentedFoxESS EV Charger Modbus TCP protocol V1.6
0x101A–0x101BFault bitsU32, bit fieldR FC03documentedFoxESS EV Charger Modbus TCP protocol V1.6
0x101C–0x101DRFID card that started the sessionU32R FC03; removed from the report, only "set / not set"documentedFoxESS EV Charger Modbus TCP protocol V1.6
0x101E–0x1021Model codeASCII, 4 registersR FC03; kept in the reportconfirmedFoxESS EV Charger Modbus TCP protocol V1.6; plausible on one device: owner's diagnostics report, #431
0x1022–0x1031Serial numberASCIInot readdocumentedFoxESS EV Charger Modbus TCP protocol V1.6
0x3000Work mode: 0 controlled (start through the app, a card or a Modbus controller), 1 plug and charge (charges when plugged in), 2 lockedU16R FC03, W FC16confirmed; OpenAmpere's write of 0 held on one deviceFoxESS EV Charger Modbus TCP protocol V1.6; plausible on one device: owner's diagnostics report, #431; write: owner report, discussion #621
0x3001Maximum charging current (the current setpoint); outside a charge the charger resets it (behaviour below; whether at once, so that a read-back right after the write already shows the reset value, is open), so OpenAmpere does not take it as the set current and writes it again as soon as the car charges; matched the maximum current (0x1013) on one idle deviceU16, ×0.1 AR FC03, W FC16documented; read plausible on one deviceFoxESS EV Charger Modbus TCP protocol V1.6; owner's diagnostics report, #431
0x3002Maximum charging power (the power setpoint); without a phase switch box it also selects the phases: below 1.4 kW paused, from 1.4 kW one phase, from 4.2 kW three phases. Matched the maximum power (0x1011) on one idle deviceU16, ×0.1 kWR FC03, W FC16documented; read plausible on one deviceFoxESS EV Charger Modbus TCP protocol V1.6; owner's diagnostics report, #431
0x3003Allowed charging time; read as 0xFFFF (probably unset) on one device, not used by OpenAmpereU16, minutesR FC03, W FC16documentedFoxESS EV Charger Modbus TCP protocol V1.6; reading: owner's diagnostics report, #431
0x3004Allowed charging energy; read as 0xFFFF (probably unset) on one device, not used by OpenAmpereU16, kWhR FC03, W FC16documentedFoxESS EV Charger Modbus TCP protocol V1.6; reading: owner's diagnostics report, #431
0x3005Validity of a command: a setpoint must be written again within this time (the watchdog)U16, s, 10–60R FC03, W FC16confirmedFoxESS EV Charger Modbus TCP protocol V1.6; plausible on one device: owner's diagnostics report, #431
0x3006Fallback current: the charger charges at this current when a Modbus controller stops writingU16, ×0.1 A, 6–32 AR FC03, W FC16confirmedFoxESS EV Charger Modbus TCP protocol V1.6; plausible on one device: owner's diagnostics report, #431
0x3007–0x3009Read in the separate block (missing on single-phase models), not interpreted–R FC03openfoxess.py
0x300AAutomatic 1/3-phase switchingU16, 0/1R FC03, W FC16confirmedFoxESS EV Charger Modbus TCP protocol V1.6; plausible on one device: owner's diagnostics report, #431
0x300BMinimum interval between phase switches; the simulated control switches phases at most this often (#440)U16, minutes, 5–30R FC03, W FC16confirmedFoxESS EV Charger Modbus TCP protocol V1.6; plausible on one device: owner's diagnostics report, #431
0x4000Electronic lock of the plug (not the work mode)U16W FC06documentedFoxESS EV Charger Modbus TCP protocol V1.6
0x4001Session control: 0 no action, 1 start, 2 stopU16W FC06documented; used by evcc's driver on real devicesFoxESS EV Charger Modbus TCP protocol V1.6; evcc-io/evcc#26218, evcc-io/evcc#31412
0x4002Phase sequence switching, only with an external phase switch boxU16W FC06documentedFoxESS EV Charger Modbus TCP protocol V1.6
0x4003RestartU16W FC06documentedFoxESS EV Charger Modbus TCP protocol V1.6

The registers marked confirmed gave plausible values in the check on one three-phase charger of an EKD system, idle with no car plugged in (#431). According to the document, read/write registers are written with function code 16 and write-only registers with function code 6. Of them OpenAmpere has written only the work mode 0x3000, and the write held on one charger (discussion #621); evcc's driver (since July 2026) writes others on real devices (evcc-io/evcc#31412). On a second three-phase charger of an EKD system OpenAmpere and evcc showed a running charge (about 4.8 kW) (discussion #621); single-phase models are not confirmed yet.

Behaviour

FactStatusSource
Modbus TCP over LAN or WLAN; port 502 according to the protocol, 1502 seen in at least one integration; unit id 1 by default; registers are holding registers read with FC03; read/write registers are written with FC16, the write-only registers 0x4000–0x4003 with FC06.documentedFoxESS EV Charger Modbus TCP protocol V1.6; #325
The charger announces Modbus TCP over mDNS as EVC-<serial>._modbus._tcp.derived#325, #327, probe.py
The wallbox that came with EKD (Ampere.IQ) systems is this charger: owners' wallboxes announce themselves as EVC-<serial> and are found by OpenAmpere's search; owners know it as "the EKD wallbox".derivedowner reports, #412
With evcc's foxess-evc template one owner's charger closed the connection at once (connection reset by peer). Likely causes: not in the Modbus TCP mode, or another client holds the connection (on EKD systems probably the previous smartbox, see below).openowner report, #412
Register lists of other charger families (e.g. holding registers 100, 300, 400) do not apply; an evcc custom charger built from them only timed out.derivedowner report, #412
Three communication modes, set in the Fox Switch app, one at a time: default (FoxESS app/cloud with PV linkage), Modbus TCP, OCPP.documentedFox Switch app manual V1.0.1; #318
In default mode the charger can be wired over RS485 to a FoxESS inverter (H3, H3 Pro, H3 Smart, see h3.md) or a shared meter and charges from surplus by itself: Fast (full current), Economic (solar first, at least 6 A from the grid), Green (surplus only). FoxESS requires self-use mode, no export limit and the order house → car → battery (the home battery may discharge into the car).documentedFoxESS energy management user manual; #318
In default mode Modbus TCP is read-only according to the Fox Switch app manual (section 8.6).documentedFox Switch app manual V1.0.1; #318
Outside the "Modbus TCP" mode some firmware answers every read with exception 6 ("server device busy").derivedevcc discussions; #318, #325
In Modbus TCP mode the watchdog fails in the unsafe direction: when the controller stops writing, the charger does not stop; after about 60 s it charges at its stored default current or at full power. Only an explicit stop ends charging, and a power setpoint written after a stop can restart it. Cost risk only; the charger stays within its rated limits.derivedowner reports from other projects, #318
A controller starts, stops and sets the current or power (0x3001/0x3002, 0x4001) only in work mode 0 ("controlled"); in plug and charge the charger starts by itself, and locked allows nothing.derivedFoxESS EV Charger Modbus TCP protocol V1.6; #318
A setpoint (0x3001/0x3002) must be written again within the validity (0x3005); otherwise the charger treats the controller as gone and charges with the fallback.derivedowner reports in evcc-io/evcc#26218
A setpoint written after a stop (0x4001 = 2) starts charging again without a start command. A controller must not refresh a setpoint while it has stopped the charger.derivedowner reports in evcc-io/evcc#26218
A current setpoint takes effect only while charging; outside a session the charger resets it.derivedowner reports in evcc-io/evcc#26218
Some chargers suddenly report work mode 2 ("locked", status 8); the previous app then shows the wallbox as locked and cannot change it.derivedowner report (#464)
Current and power setpoints are held in RAM and lost on a power cut; configuration values are probably stored. Automatic 1/3-phase switching follows the power setpoint.derived#318
The previous smartbox of EKD (Ampere.IQ) systems is a Modbus TCP client of the charger: its settings page lists the charger as "Ampere.ChargePro Bridge", Modbus TCP, host EVC-<serial>.local, unit id 1, port 502, marked as not configurable. So the box competes with OpenAmpere and evcc for the charger's connection(s).derivedan owner's screenshot of the box's settings page, #427; #412
While the previous smartbox is powered, OpenAmpere cannot read the charger: the connection on port 502 is refused, or it is accepted but the answers carry foreign transaction ids and then time out. With the box cut from power the check reads all blocks at once on port 502, unit id 1, FC03; port 1502 refused. Whether the charger allows only one client or mishandles concurrent clients is open.confirmed (one device)owner's diagnostics report, #431
On a second EKD system every TCP connection to port 502 timed out (evcc's foxess-evc template) while the box was connected, although the charger answered ping. With only the box's LAN cable pulled (the box stayed powered) evcc connected, and evcc and OpenAmpere showed a running charge of about 4.8 kW. So it is the box's network connection that blocks the charger; pulling its LAN cable is enough.confirmed (second device)owner report, discussion #621, #622
On that charger, starting and stopping a charge from evcc had no effect while the charger was read. First guesses were the work mode (not "controlled", 0x3000) or the communication mode. Later evcc's start and stop worked on the same charger even while OpenAmpere showed "plug and charge" (row below), which makes the work mode an unlikely cause; the box still holding a connection is the more likely one. Not settled.openowner report, discussion #621
On the same system the charger later was not reachable at all (no ping, no answer on port 502) while the box's LAN cable was pulled, although a few days earlier pulling it had freed the charger; why is open (the charger may get its network through the box). Changing the box's Modbus target port for the charger from 502 to 503 in the box's web interface freed port 502 for OpenAmpere and evcc while the box stayed connected; the box then reports errors for the charger. With that, evcc started and stopped charging (seen in the car's app), while OpenAmpere's write of work mode "controlled" (0x3000) was refused. The Fox Switch app refused to add the charger ("SN unterstützt keine Bindung"). Which work mode and communication mode the charger is in is not recorded.derived (one system)owner report, discussion #621, #647
On that system the charger and the box are both connected to the same switch, and neither has a second LAN port. Still, with the box's LAN cable pulled the router showed the charger as offline and it answered neither ping nor Modbus; with the cable back it answered ping again. Why the charger's network depends on the box is open.derived (one system)owner report, discussion #621
On that system OpenAmpere's write of the work mode "controlled" (0x3000) was later kept, after the box's port had been moved to 503 (and OpenAmpere moved to a faster computer); which of the two made the difference is not known. With "controlled", evcc started, stopped and limited charging. Starting and stopping from evcc had also worked while OpenAmpere showed "plug and charge". evcc's driver writes neither the work mode (0x3000) nor start/stop (0x4001): it pauses with the power setpoint 0x3002 = 0 and charges with a setpoint above it, refreshed within the validity 0x3005, so that start and stop in "plug and charge" were writes of 0x3002 (evcc version on that system not recorded).confirmed (one device); evcc's use of 0x3002: documented in its codeowner report, discussion #621
With evcc stopped during a charge at about 4.6 kW, the charger went on charging at about 1.9 kW (seen in the car's app), so it fell back to a lower current instead of stopping. About 1.9 kW is below the lowest three-phase power (6 A × 3 ≈ 4.1 kW), so the fallback ran on one phase (about 8 A) or the car's figure is not exact; open. After evcc was started again it set the current again within 1–2 minutes and could stop the charge. The fallback current (0x3006) and the validity (0x3005) evcc had set were not recorded.confirmed (one device)owner report, discussion #621
Some chargers accept a single Modbus client only: a charger read by evcc may refuse a second connection or drop evcc's for a moment. The real number of connections is unknown.openprobe.py, #318
The installer's binding of the charger in the FoxESS app expires after 6 hours; owners can bind it to their own FoxESS cloud account.deriveddesk research in #318
OCPP: 1.6J works; 2.0.1 rejects charging profiles (FoxESS support recommends 1.6J). No phase switching over OCPP. After a server restart the charger can take many minutes to reconnect. In OCPP mode the FoxESS app/cloud and evcc lose control; the charge point id is the serial number. See wallboxes.derived#318
Newer models have a hardware input for the grid operator's dimming signal (§ 14a EnWG).derived#318
The FoxESS H3 has no registers for an attached charger; its power is part of the house load.documentedFoxESS inverter Modbus definition; #318

Decisions in OpenAmpere

DecisionWhyIssue/PR
First step is read-only: a generic Modbus read tool, the wallbox check and an OCPP listener. FoxESS owners with PV linkage keep the default mode; OpenAmpere only displays the charger.Registers are unconfirmed; the watchdog fails unsafe.#318, #324, #325, #326, #327, #328, #333
The check tries port 502, then 1502, unit 1, and reads only with FC03.Both ports are seen.#325, #327
The serial number (0x1022) is not read; energy counter and RFID card words are removed from the report (only "plausible" and "set / not set" remain); the serial in the mDNS name is masked.They identify the owner.#325, #327, foxess.py
The check tells apart a name that cannot be resolved (outcome unresolved: enter the IP address; .local names never resolve in the Home Assistant app), a refused connection (connection_refused: the address answers but takes no Modbus connection, so it is another device or another client such as the previous smartbox or evcc holds the connection) and no answer at all (unreachable). Why a port failed is recorded per port in the report; the plain connection that tells refused from timed out is made only after the Modbus client failed.Owners copy the box's EVC-<serial>.local name, and one outcome for all three cases gave them no hint what to do.#427
The check's texts for a refused connection, a connection without a proper answer and a connection closed at once name the previous smartbox first (disconnect it from the network, by pulling its LAN cable, or from power for the check), then evcc, then another device or a wrong unit id.The box blocked the check on a real device; on a second one pulling its LAN cable was enough.#431, #624
The setup's network search marks a host that announces EVC-<serial>._modbus._tcp as a FoxESS wallbox, does not open a Modbus connection to it and does not offer it as the inverter. A busy device it cannot identify is called "Modbus-Gerät, gerade belegt", and the hint names the wallbox held by the previous smartbox. In the Home Assistant app there is no mDNS, so only the neutral label applies.While the box was powered, the charger showed up in the search as "Wechselrichter, gerade belegt" next to the real inverter, and the owner doubted which address is the wallbox.#433
OpenAmpere assumes the charger allows one Modbus connection: never evcc and OpenAmpere on the same charger. With evcc connected next to a wallbox OpenAmpere reads directly (switched on), the app warns when evcc has no charge point (a wallbox left in evcc is the likely reason), and then replaces evcc's "sponsor token missing" error with advice to delete that wallbox in evcc, enter a token if evcc controls another one, or disconnect evcc; with charge points of its own evcc's error stays as it is (the token is what its wallbox needs) and the direct setup only notes that one wallbox must not be set up in both. The setup opens on "direct" when such a wallbox exists and evcc has no charge point. evcc does not report its chargers' addresses, so the warning cannot tell whether it is the same wallbox.The number of connections is unknown. An owner whose charger was still set up in evcc (failing on the sponsor token) saw only evcc's advice to buy a token.#318, #535
The charger is a wallbox OpenAmpere shows live, read only: a model in wallbox/native.py whose only mode is "manual". The other modes are refused when saved or chosen and offered neither in the app nor in Home Assistant (sensors only; no current sensor, the setpoint is not known). There is no write path: its Modbus connection can only read with FC03, and a test fails on any write request. Its power counts in the house load like any wallbox, but the surplus control never acts on it. The other modes later became a simulation (row for #440 below), and the work mode became writable on request (row for #464 below).No write register is confirmed, the watchdog fails in the unsafe direction, and § 14a is not settled.#439, #318
The live view opens one short connection per poll (every 10 s; after a failure again after 15 s, 30 s, … up to 5 minutes) and closes it after reading. Values older than 35 s are not used. The wallbox check, the device reader and the connection test of the setup take turns with the poll of a charger set up at the same address and port, so OpenAmpere never holds two connections to it. A wallbox at the inverter's address and port is refused in the setup.The number of connections the charger allows is unknown, and the previous smartbox holds it on EKD systems.#439, #431
The live view keeps its own waiting time after a failure (up to 5 minutes) while the inverter's became at most 60 s, and has no "Connect now".A charger allows very few connections (possibly one) and the previous smartbox may hold it; asking it more often while it refuses only adds attempts.#640, #641
In the live view the status, not 0x1005, tells whether a car is plugged in (status 1–5 and 9). Status 9 counts as charging, 8 (locked) as unknown with the work mode "locked". The power is the sum of voltage × current of the phases, the power register (0.1 kW) only without current; a charge counts from 100 W; under real control status 9 (switching phases) also counts as a running charge, whatever the power (#478).0x1005 read 1 without a car; 0.1 kW steps are coarse.#439, #431
A charger that does not answer is shown as not reachable without old values; the app names the previous smartbox first (it must stay disconnected from the network or from power for the live view), then evcc or another program.Like the check, where the box blocked the charger on a real device.#439, #431, #624
The live view does not read the energy counters, the card number, the model code and the serial number (0x1016–0x1031).Not needed for the display; they identify the owner.#439
The modes off, solar, min + solar and fast are offered as a simulation only: native.py decides as for the dé wallbox (surplus, margin, two checks in a row, minimum on and off time, raising at most every 30 s, the owner's waiting time) with the charger's own limits (0x1013, 0x1014), and logs every start and stop it would have made, marked as a simulation and not sent, whatever the master switch and the test mode say. Changes of the current are collected and logged at most every 5 minutes per wallbox as one entry (the current then and the lowest and highest current since the entry before); a collected change is logged before the next stop or the end of the plan, and nothing while nothing changes, so the simulation, which also runs with the master switch off, does not bury real changes in the control log (review of #443). Without the owner's yes to real control the model stays read only for charging: its Modbus connection for reading still cannot write, and a test fails on any write request (the work mode is written on request, row for #464 below; real control, row for #465 below). The plan is kept in memory, taken over from the charger when a car is plugged in, and dropped with the mode "manual" or a restart. A charge the charger started by itself counts as its own; letting go of a charge the simulation started logs the explicit stop real control would send. Phases follow the automatic 1/3-phase switching (0x300A): one phase below the lowest three-phase power (6 A × 3), three from there, switched at most once per the charger's interval (0x300B, 5 minutes if not told). The plan never counts as load or takes surplus from other devices; the charger's real power stays in the house load. Home Assistant gets no mode for it.Shows on real data how the control would behave (when it would set what, how often, compared with what the charger does by itself) before anything may be written. The phase rule is derived from the protocol (switching follows the power setpoint), not confirmed on a device; the 5 minutes used when the charger does not report 0x300B are an assumption of OpenAmpere (open). The heartbeat and the fallback current (0x3006) are not simulated: they only matter once OpenAmpere writes (row for #465 below).#440, #318
Register addresses are used as facts only, nothing copied from the FoxESS document; evcc's FoxESS driver (not MIT) and two MIT Home Assistant integrations that derive from a project without a license are not used.License and permission of the sources.#318, #325, #327
Decided for control over Modbus (#318), done in #465: a one-time fallback current of 6 A with the owner's consent, an explicit stop on planned shutdown, a heartbeat of 30 s or less, an explanation in the app and an exception noted in AGENTS.md. OpenAmpere does not take on the § 14a role; the charger's own dimming input takes precedence and OpenAmpere never works around it. Whether the charger reports a dimming by the grid operator over Modbus is open, so OpenAmpere cannot yet hold back a higher current while it dims.Fail-safe behaviour despite the unsafe watchdog; legal topics are settled in the issue first.#318
The work mode (0x3000) is the one register OpenAmpere writes to the charger: chosen by the owner in the app after a question, with function code 16, only with the master switch on (logged, not sent in test mode), read back and logged. A ModbusWallbox writes only the registers it was made with (writable); the poll and the check get none.A charger that went "locked" cannot be released with the previous app; a stored setting needs no watchdog.#464
Real control (#465) only per wallbox after the owner agreed in the app, as a test: the modes off, solar, min + solar and fast write the current (0x3001, FC16) and start or stop (0x4001, FC06), only in work mode "controlled". Before the first write after a (re)connection 0x3005 = 60 s and 0x3006 = 6 A, nothing else written unless both read back; real control is switched on and off only with the question in the app, never by saving the wallbox list; test mode during a charge OpenAmpere started stops it and lets go; while the car charges the current is written again every 25 s (not logged), never after a stop; the current written before start or stop; on a planned shutdown and when OpenAmpere lets go (also the mode "manual") a charge it started is stopped; a stop never waits for the fallback current to be set again. Under real control OpenAmpere refuses any work mode other than "controlled"; a change outside OpenAmpere during a charge it started makes it send a stop and let go. A charger that does not read back 0x3005/0x3006 is not controlled for 15 minutes, and a charge OpenAmpere started is stopped. A lower current the charger keeps while charging (a limit of its own, or perhaps a dimming) counts as its highest current for 15 minutes, until the mode changes or OpenAmpere lets go; then the mode's current is asked again. With automatic switching on (0x300A) a three-phase charger gets its phases through the power setpoint 0x3002 (#478): 4.1 kW for one phase, for three the power setpoint the owner had before OpenAmpere first wrote it (else 0x1011; a value of exactly 4.1 kW counts as a leftover of OpenAmpere's own cap), written with the current, refreshed with the heartbeat, never after a stop, at most once per 0x300B. A one-phase cap OpenAmpere set (stored before it is written, its end only after the write, so also known after a restart) is put back to the owner's value before every stop, when OpenAmpere lets go (also without a charge; with a car connected that does not charge, followed by a stop, so the setpoint cannot restart a paused charge) and when automatic switching is turned off (tried again at most every 15 minutes if the charger does not take it); while OpenAmpere controls, it decides the phases and a power set in the FoxESS app meanwhile is overwritten (the value from before the control is what it puts back); the cap is put back only while the charger still reads it (another value means the owner set one since, and the cap is forgotten); a power limit the owner set is never raised: with an owner's setpoint below 4.2 kW OpenAmpere does not switch phases at all, and the one-phase value never exceeds the owner's. Without automatic switching 0x3002 stays untouched.The watchdog fails unsafe, so the owner decides; the pitfalls reported by owners (#463).#318, #465
A restored backup keeps the running installation's consent per wallbox (real control off for a wallbox it does not have; a difference is noted in the control log entry of the restore) and its record of which charges OpenAmpere started and stopped (wallbox_owned, wallbox_stopped, like remote_command for the inverter). Stored wallboxes, also those OpenAmpere still has to let go of, go through the address checks of the app (home network, not the inverter's address and port); one that fails is ignored with a warning in the log.A backup must neither switch on real control without the question in the app nor make OpenAmpere stop a charge it did not start or forget one it did; never write to an address the app refuses.security fix, GHSA-wx8q-mh5w-82jr
A minimum current (0x1014) above the owner's highest current (of the app or of the mode): as for the dé wallbox, no start, no current written, a running charge stopped and a note in the app that names the limit to change (OpenAmpere's highest current or the mode's, never the charger's own maximum: its lowest step is clamped to 0x1013) and goes while OpenAmpere controls nothing; the simulation shows that it would not charge.The owner's limit is an upper bound; the charger takes no current below its minimum.#481