Solarmax MAX.STORAGE ("AMPERE.Storage")
Not official manufacturer information: compiled by the OpenAmpere contributors, can be incomplete or wrong. Changing inverter settings can affect the warranty and grid rules; no affiliation with Solarmax or EKD; not legal advice. See the device knowledge README.
Applies to: Solarmax MAX.STORAGE and MAX.STORAGE Ultimate hybrid inverters · Sold as: "AMPERE.Storage" (EKD,
the 10 kW Ultimate, about 2022–2023) · OpenAmpere: driver solarmax (src/openampere/drivers/solarmax/),
register map solarmax_max_storage · Support: display only · Confirmed on a real device: partly (detection,
live values and the grid sign from a diagnostics report, zeros in the "Connectivity+" registers on two devices; the
battery sign from the energy balance of one report)
Summary
- Modbus TCP on port 502, unit id 1, input registers (FC04), addresses from 0, 32-bit values with the low word first (unlike FoxESS and SAJ).
- The live values (PV, battery, house, grid, state of charge) are readable on every device. Everything from register 130 on, including the lifetime energy counters, needs "Connectivity+", which only Solarmax unlocked; without it OpenAmpere integrates the powers into energy counters of its own (#636).
- Signs differ: Solarmax counts battery charging and grid export as positive; the driver turns both around.
- OpenAmpere only reads. EKD switched the storage function of these devices off remotely in 2025 (names.md); OpenAmpere must never switch it on again.
- Solarmax is insolvent; the old apps are gone and the portal costs money, so OpenAmpere may be the only free local app left for these owners (#519).
Registers
All input registers (FC04), unit id 1. 32-bit values: low word at the lower address.
| Register | Meaning | Type, scale, sign | R/W | Status | Source |
|---|---|---|---|---|---|
| 100–101 | Serial number of the control unit | U32 | R | documented | Solarmax list |
| 102 | Firmware of the control unit, e.g. 344 = 3.4.4 | U16 | R | documented | Solarmax list |
| 103 | Device state: 0 unknown, 1 ok, 2 warning, 3 error | U16 | R | documented | Solarmax list |
| 105 | Nominal AC power | U16, W | R | documented | Solarmax list |
| 110–111 | PV power (DC) of this inverter | I32, W | R | documented, derived (type) | Solarmax list; evcc |
| 112–113 | PV power (DC) of the whole plant, other connected inverters included | I32, W | R | documented | Solarmax list |
| 114–115 | Battery power, + = charging, − = discharging | I32, W | R | documented, derived (type, sign) | Solarmax list; evcc (scale −1); #647 |
| 116–117 | House consumption ("Eigenverbrauchsleistung") | I32, W | R | documented | Solarmax list |
| 118–119 | Grid power, + = export, − = import | I32, W | R | documented, derived (type), confirmed (sign) | Solarmax list; evcc (scale −1); #596 |
| 120–121 | AC power of the whole PV plant | I32, W | R | documented | Solarmax list |
| 122 | State of charge | U16, % | R | documented | Solarmax list; evcc |
| 123 | Usable battery capacity | U16, whole kWh | R | documented | Solarmax list |
| 124 | Energy stored now | U16, whole kWh | R | documented | Solarmax list |
| 125, 126 | Power of MPPT 1 and 2 | U16, whole kW | R | documented | Solarmax list |
| 130–138 | Battery limits, pack voltages, cell temperatures ("Connectivity+") | R | documented | Solarmax list | |
| 140–143 | AC voltages L1–L3, grid frequency ("Connectivity+") | R | documented | Solarmax list | |
| 150–151 | PV energy of this inverter and those connected to it ("Connectivity+") | U32, whole kWh | R | documented | Solarmax list |
| 152–153 | Energy exported to the grid ("Connectivity+") | U32, whole kWh | R | documented | Solarmax list |
| 154–155 | Energy imported from the grid ("Connectivity+") | U32, whole kWh | R | documented | Solarmax list |
| 156–157 | Energy charged into the batteries ("Connectivity+") | U32, whole kWh | R | documented | Solarmax list |
| 158–159 | Energy discharged from the batteries ("Connectivity+") | U32, whole kWh | R | documented | Solarmax list |
| holding 140–143 | Battery power setpoint, watchdog, active power limit in % ("Connectivity+") | R/W | documented; not used by OpenAmpere | Solarmax list |
"Solarmax list" is "MAX.STORAGE / MAX.STORAGE Ultimate ModbusTCP Datenpunktliste" (2024-09-11, firmware 3.4.4 and later). The input registers 140–143 and the holding registers 140–143 are different tables.
Behaviour
| Fact | Status | Source |
|---|---|---|
| Solarmax's list marks 100–126 as available on every device and 130–159 as "Connectivity+" only. | documented | Solarmax list |
| evcc reads grid 118, PV 110, battery 114 and state of charge 122 as signed 32-bit values with the low word first, and dropped the PV energy register because it counts only whole kWh. Battery control in evcc needs "Connectivity+" and firmware 3.4.4. | derived | evcc-io/evcc templates/definition/meter/solarmax-maxstorage.yaml at 8796395558 (MIT) |
| Tinkerforge's energy manager reads the same addresses and also 112, 116 and 120: a second, independent reading of these registers. | derived | Tinkerforge/esp32-firmware software/src/modules/meters_modbus_tcp/solarmax.py (LGPL-2.1, facts only) |
| geeks-r-us/solarmax2mqtt reads the device over Modbus TCP; geeks-r-us/maxstorage_ultimate reads the web interface on port 80 instead (no license: facts only). The older Solarmax "MaxTalk" protocol (port 12345) belongs to Solarmax string inverters, not to MAX.STORAGE. | derived | the repositories named (solarmax2mqtt MIT) |
The web interface shows firmware, hardware version and an "Ident"; the device can be reached as <Ident>.local. | derived | geeks-r-us/maxstorage_ultimate |
| The list defines holding registers 140/141 as one 32-bit setpoint; evcc writes them as two 16-bit limits with 142 as watchdog, which owners say works. Only matters for control. | open | Solarmax list; evcc template |
| Solarmax is in preliminary insolvency proceedings since 2024-11-29 (court Neu-Ulm); no buyer is reported. | documented | solarserver.de, 2024-12-06 |
| The app and the device's web interface keep working inside the home network by IP address; the cloud portal came back in 2025 as a paid subscription run by another company, and the old Solarmax apps are no longer in the App Store. | derived | photovoltaikforum.com threads 243977 and 252527 (2025); research in #519 |
| EKD switched the storage function off remotely in September 2025 and released it after a fuse was fitted in the battery line. How the registers look while it is switched off is not known. | derived (shutdown), open (registers) | names.md; photovoltaikforum.com thread 252527 |
| "AMPERE.Storage" is the 10 kW variant (three-phase, 2 MPPT, 6–15 kWh in 3 kWh packs); MAX.STORAGE Ultimate also exists with 6, 8, 12 and 15 kW, and the list covers the older MAX.STORAGE too. Register 105 tells them apart. | documented | EKD datasheet "AMPERE.Storage" (2022-07); Solarmax datasheet MAX.STORAGE Ultimate (2021-12) |
| On the first owner's device (OpenAmpere 0.41.0, Docker) detection at unit 1 over port 502 with FC04 worked and 100–126 read. With no PV and the battery idle, the diagnostics showed grid power of about −3 kW and the same house power in Solarmax's signs: 118 is negative for import, as the list says. The "Connectivity+" registers 130–143 and 150–159 answered with zeros, not with an exception, so this device has no energy history. The owner says the directions of the flows are right as far as they could tell. | confirmed (detection, live values, grid sign, zeros without "Connectivity+"), open (battery sign) | owner's diagnostics report by e-mail, summarised in #596 |
| On a second owner's device (an EKD unit, firmware within the list's range, OpenAmpere 0.41.0) the diagnostics again showed the live values read and the "Connectivity+" registers 130–143 and the counters 150–159 answering with zeros. Before #636 OpenAmpere therefore had no energy history and every day value stayed at 0, while the live values were right. In the same reading PV covered the house with a little left over, and both 114 (battery) and 118 (grid) were small and positive: charging and export in Solarmax's signs, as the list says. The values are rounded to 100 W, so this is weak evidence for the battery sign. | confirmed (zeros without "Connectivity+" on a second device), derived (battery sign, one rounded reading) | owner's diagnostics report in #636 |
| In the same report the check of further connections got no answer on any of three extra connections, and the main connection was closed during it; the log also shows Modbus answers that belonged to an earlier request (transaction id one lower). The owner had also run the tablet app of the system then. A second run with the tablet app stopped gave the same result: the device serves one Modbus TCP client at a time, like the M-TEC module (mtec), and a second connection drops the first. | confirmed (one device, two runs) | owner's diagnostics report and follow-up comment in #636 |
| A later report of the first owner (0.42.0) was taken while a car charged from PV at a low state of charge. In Solarmax's signs: PV about 3.9 kW, battery about −200 W, grid about −200 W, house (116, read on its own) about 4.3 kW. PV plus battery discharge plus grid import equals the house only with 114 read as + = charging; turned around, the sum is 400 W short, more than the rounding to 100 W explains. The house also contains the charging car (about 3.9 kW in the wallbox's own reading). | derived (battery sign, one reading) | owner's diagnostics report by e-mail, summarised in #647 |
Decisions in OpenAmpere
| Decision | Why | Issue/PR |
|---|---|---|
Display only: every write method refuses, supports_control is off. | EKD switched the storage function off remotely; control also needs "Connectivity+". OpenAmpere never switches it on again. | #515, #519 |
| Detected after FoxESS and SAJ, at unit 1, by reading 100–126 with FC04. The device counts as a Solarmax only if firmware (100–999), device state (0–3), nominal power (1–30 kW), state of charge and capacity (at most 100) are all plausible. | Detection must not claim another device; SAJ also answers at unit 1, but not with FC04 at 100. | #519 |
Without the counters of "Connectivity+", PV power is the inverter's own DC power (110); the rest of the plant (112 − 110) is shown as a second PV inverter the owner can count, once it was more than 50 W at least once, or with 0 W as soon as the owner counts one (pv.external). With the counters, PV power is the whole plant's (112) and there is no second inverter to count. | 112 includes other inverters connected to the MAX.STORAGE; without one the app must not offer to count it. What was seen is not stored, so after a restart at night a counted inverter would otherwise be unknown until the sun comes back. The PV counter (150) already includes the connected inverters: counting one on top would count its energy twice. | #519 |
| The energy counters (150–159) are used only when they answer and are not all zero, and are no longer asked for after a refusal, or after three reads in a row without an answer if they never answered (counters that answered before are then asked once a minute); there is no load counter, the consumption is their balance. | Without "Connectivity+" the device may refuse them, answer zeros or not answer; zeros would look like counters that start at 0, and the live values must never wait for them. | #519 |
| Without counters (refused, no answer or all zero) the collector integrates the live powers into lifetime counters of OpenAmpere's own (PV 110, grid 118 and battery 114 split by direction; left Riemann sum, nothing across a gap of more than 2 minutes), kept in the database with each reading so they go on after a restart. Integration starts only once the device is known to have no counters (zeros, refused or never answered), not after one missed read. The energy history, the day values and the counters for Home Assistant come from them. A second inverter the owner counts keeps its own integral (#419). Once real counters answer they are used instead. | Before, every day value stayed at 0 on devices without "Connectivity+", which seems to be the usual case for EKD's units. A gap is left empty rather than guessed. Energy from before the update cannot be worked out afterwards: the history starts with it. | #636 |
The connection test of the diagnostics is skipped (SINGLE_CONNECTION). Unlike M-TEC, the setup has no notice to switch other readers off. | The device serves one connection: the test only drops OpenAmpere's own connection and tells nothing new. The tablet app apparently does not hold the Modbus connection: OpenAmpere read the device while it ran (derived, one owner). Another Modbus reader (e.g. evcc) would still keep OpenAmpere out; no owner has reported one yet. | #636 |
| Device state 3 (error) is reported as a fault; 2 (warning) is not. | A warning is no fault the owner must act on. | #519 |
| The diagnostics show the powers with Solarmax's own signs (rounded) and whether the "Connectivity+" registers answer, without the serial number and without counter values. | So the first owner's report can confirm the signs. | #519 |
Open questions
- Whether port 502 answers with factory settings on every device (it did on the first owner's).
- The sign of 114 on a real device: the list and evcc agree, the first owner says the directions are right, and the energy balance of one report only adds up with charging as positive (#647), but the battery power was small in every report so far; a report with the battery clearly charging or discharging would settle it (#596).
- What 103, 114, 123 and 124 show while EKD's switch-off is active, and whether PV keeps producing then.
- Whether 116 is the whole house consumption when a second inverter is in the house.
- Which firmware EKD's units run; the list is for 3.4.4 and later (the first owner's unit is within it).
- What the type plate says, and whether EKD's units carry "AMPERE" on the housing.
Sources
- Solarmax, "MAX.STORAGE / MAX.STORAGE Ultimate ModbusTCP Datenpunktliste", 2024-09-11: handed to owners and attached by them to public evcc issues; no longer on solarmax.com. Facts only, in own words.
- evcc-io/evcc, template
solarmax-maxstorage(MIT), commit 8796395558. - EKD datasheet "AMPERE.Storage" (2022-07); Solarmax datasheet MAX.STORAGE Ultimate (2021-12).
- Tinkerforge/esp32-firmware (LGPL-2.1), geeks-r-us/solarmax2mqtt (MIT), geeks-r-us/maxstorage_ultimate (no license): facts only.
- photovoltaikforum.com threads 243977 and 252527 (owners, 2025); solarserver.de (2024-12-06).
- Research comment in #519.