Weidmüller AC SMART ("AMPERE.Charge")
Not official manufacturer information: compiled by the OpenAmpere contributors, can be incomplete or wrong. No affiliation with Weidmüller or EKD; not legal advice. See the device knowledge README.
Applies to: Weidmüller AC SMART ECO, VALUE and ADVANCED wallboxes · Sold as: "AMPERE.Charge" (EKD, the VALUE
with 11 kW, about 2023–2024) · OpenAmpere: wallbox module weidmueller_ac_smart (src/openampere/wallbox/weidmueller.py)
· Support: display only (live view and the read-only check of the setup) · Confirmed on a real device: no
(built from Weidmüller's register document and the simulator)
Summary
- Modbus TCP is on at delivery: port 502, unit id 255, holding registers (FC03). It accepts only one Modbus client at a time: while evcc or the previous smartbox holds the connection, OpenAmpere gets none.
- Values of 4 bytes come with the low word first; the document does not say so, evcc found it on real devices.
- OpenAmpere only shows the wallbox: state, power, current and voltage per phase, the energy of the charge, its limits. It never writes; the only mode is "manual".
- Control would work as a satellite box (a load management current renewed within a timeout). When the controller goes away, the wallbox charges on with its fallback current, like the FoxESS charger (foxess/ac-charger.md): control needs the same safety rules and a confirmation on a real device first (#523).
Registers
All holding registers (FC03), unit id 255. "4 bytes" = two registers, low word first.
| Register | Meaning | Type, scale, sign | R/W | Status | Source |
|---|---|---|---|---|---|
| 300 | Current offered to the car | U16, A | R | documented | Weidmüller document |
| 301 | Vehicle state, letter A–F in the low byte (A no car, B connected, C/D charging, E/F error) | ASCII | R | documented | Weidmüller document |
| 302 | State of the charge controller, 0–15 (3 waiting for authorisation, 11 charging, 12 paused, 14/15 error) | U16 | R | documented | Weidmüller document |
| 303, 304 | Relay on, PWM to the car on | U16 | R | documented; read, not used | Weidmüller document |
| 305–306 | Duration of the charge since the authorisation | 4 bytes, s | R | documented | Weidmüller document |
| 307–311 | Available / maintenance, cable current limit (INT, −1 = error), lock closed, charge released, cable or socket | U16 | R | documented; read, not used | Weidmüller document |
| 317 | Phases: 0 = one, 1 = three (stored) | U16 | R/W | documented; which one a satellite follows is open | Weidmüller document |
| 318 | Phases set by the load management (not stored) | U16 | R/W | documented | Weidmüller document |
| 319 | Installed phases (enum, 0 = one phase) | U16 | R | documented | Weidmüller document |
| 400–405 | Voltage L1–L3 (RMS) | 4 bytes each, mV | R | documented | Weidmüller document |
| 406–411 | Current L1–L3 (RMS) | 4 bytes each, mA | R | documented | Weidmüller document |
| 412–417 | Average current L1–L3 | 4 bytes each, mA | R | documented; read, not used | Weidmüller document |
| 418–419 | Active power, sum | 4 bytes, mW | R | documented | Weidmüller document |
| 420–429 | Reactive and apparent power, power factor, frequency, energy of the last charge in Ws | 4 bytes each | R | documented; read by the check, not used | Weidmüller document |
| 430–431 | Energy of the last (current) charge | 4 bytes, Wh | R | documented | Weidmüller document |
| 432 | Temperature of the sensor | INT, unit not stated | R | documented, open (unit) | Weidmüller document |
| 457–460 | Total energy | 8 bytes, Wh | R | documented; stays 0 on ECO and VALUE (derived) | Weidmüller document; evcc-io/evcc#35118 |
| 700 | Current limit of the wallbox | U16, A | R | documented | Weidmüller document |
| 701 | Current limit set at installation (stored) | U16, A | R/W | documented | Weidmüller document |
| 702 | Current limit of the user (stored) | U16, A | R/W | documented | Weidmüller document |
| 704 | Plug and charge (charging without authorisation) | U16 | R/W | documented | Weidmüller document |
| 705 | External charge release (not stored) | U16 | R/W | documented | Weidmüller document |
| 846–851 | Firmware version | ASCII, 12 bytes | R | documented | Weidmüller document |
| 7132–7133 | OCPP server port (stored) | 4 bytes | R/W | documented; not used | Weidmüller document |
| 7209 | OCPP on (stored, needs a restart) | U16 | R/W | documented; not used | Weidmüller document |
| 995 | Modbus over 0 = Ethernet, 1 = WLAN (stored, needs a restart) | U16 | R/W | documented | Weidmüller document |
| 11000 / 11001 | Satellite box / control box (stored) | U16 | R/W | documented | Weidmüller document |
| 11050–11051 | Timeout of the satellite box (not stored) | 4 bytes, ms | R/W | documented | Weidmüller document; application note |
| 11052 | Current from the load management, 0 or 6–32 (not stored) | U16, A | R/W | documented | Weidmüller document; application note |
| 11053 | Error of the control box that stops charging | U16 | R/W | documented | Weidmüller document |
| 11054 | Fallback current: the current it charges with when the control box is gone (not stored) | U16, A | R/W | documented | Weidmüller document |
"Weidmüller document" is "AC SMART ECO / VALUE / ADVANCED Modbus-Register", Dok.-Nr. 2933050000 Rev. 02 (2023-06), public on Weidmüller's website. It warns not to write the stored (non-volatile) registers cyclically. It lists no registers at 312–316, 433 and 703; OpenAmpere reads no block across them.
Behaviour
| Fact | Status | Source |
|---|---|---|
| Modbus TCP is preconfigured at delivery (port 502, unit id 255) and allows only one Modbus client; Modbus over WLAN instead of LAN is a setting that needs a restart. | documented; derived (owners confirm the one-client limit) | operating manual "AC SMART ECO/VALUE/ADVANCED"; photovoltaikforum.com thread 227016 (2024) |
| 32-bit values come with the low word first. | derived | evcc-io/evcc#15261, evcc-io/evcc#35118 and evcc-io/evcc#35123 (behaviour seen on devices; evcc's charger/weidmüller.go is not MIT, nothing taken from it) |
| Control as a satellite box: write 11052, then set 11050 again before it runs out (the application note's example: 60 s). | documented | application note "Einbindung der AC Smart in Lade-/Lastmanagement" (2023-05, attached in evcc-io/evcc#15261) |
| Without its control box a satellite charges at the minimum of 6 A (manual); evcc saw it fall back about 65 s after evcc stopped. It charges on, it does not stop. | documented (manual), derived (evcc) | operating manual; evcc-io/evcc#35123 |
| A factory reset sets 11000 back to 0 but keeps 702; with 11000 = 1 and 702 = 0 the wallbox does not charge at all. | derived | evcc-io/evcc#35118, evcc-io/evcc#35123 |
| The wallbox can itself read a meter or inverter over Modbus TCP (registers 495, 5606–5677); EKD owners entered inverter addresses there, so it may hold one of the inverter's Modbus connections. | documented (registers), derived (EKD use) | Weidmüller document; photovoltaikforum.com thread 227016 |
| EKD's "AMPERE.Charge" is type CH-W-S-A11-P7.5-V (VALUE, 11 kW, 7.5 m cable); the type plate does not print "VALUE", the last letter gives the variant (E/V/A). | documented (type), derived (letters) | EKD datasheets "AMPERE.Charge" (2023-04, 2023-12) |
| Weidmüller's "AC SMART App" works over Bluetooth, WLAN or LAN without a cloud account. | documented | App Store listing |
| No Home Assistant, ioBroker or openWB module for the AC SMART was found; one ioBroker owner uses the generic Modbus adapter. | derived | research in #523; evcc-io/evcc#15064 |
| At delivery the wallbox has the fixed address 192.168.0.8 with DHCP off; its local web interface has an admin role (electrician) and a user role, and load management and OCPP are set there. | documented | operating manual |
| The type plate shows the article number (2911240000 for EKD's type); an RFID field on the front means VALUE or ADVANCED, an energy display ADVANCED. | documented (variants), derived (article number) | operating manual; EKD datasheets |
| The article is said to be discontinued (orderable until about 2025-04), while the AC SMART line goes on. | open | search snippet of Weidmüller's datasheet page (page itself not reachable) |
Decisions in OpenAmpere
| Decision | Why | Issue/PR |
|---|---|---|
| Display only: never written, only the mode "manual"; its power counts in the house load like any wallbox. | Nothing confirmed on a real device; when OpenAmpere stops, the wallbox would charge on with its fallback current. | #523 |
| One short connection per read, closed right away. | The wallbox takes only one Modbus client; holding it would lock out the owner's app and other tools. | #523; wallbox/modbus.py |
| A voltage above 400 V, a current above 80 A, a power above 30 kW, a charge above 200 kWh or longer than a week are not shown; with such a power the state is unknown. | That is what the other word order would give: better no value than a wrong one. | #523 |
| The check keeps the total energy (457–460) out of the report, only whether it is plausible. | An exact counter identifies the owner. | #523 |
Open questions
- The word order on an EKD unit, and which firmware they run.
- What 11054 holds after power-up and whether it can be 0; what the wallbox does when 11050 runs out.
- Which phase register a satellite follows, 317 or 318.
- Whether something else (the previous smartbox, evcc) still holds its Modbus connection on EKD systems.
- The unit of the temperature (432).
- Whether the wallbox reads the inverter itself on EKD systems (495, 5606) and so holds one of its Modbus connections.
- Whether the AC SMART App works without the internet.
- Whether it measures the voltages behind its contactor: then an idle wallbox would show one phase, and the live view should take the installed phases from 319 instead.
Sources
- Weidmüller, "AC SMART ECO / VALUE / ADVANCED Modbus-Register", 2933050000 Rev. 02, 2023-06 (public); operating manual "AC SMART ECO/VALUE/ADVANCED"; application note "Einbindung der AC Smart in Lade-/Lastmanagement" (2023-05). Facts only, in own words.
- evcc-io/evcc#15261, evcc-io/evcc#35118 and evcc-io/evcc#35123: behaviour seen on devices (the module
charger/weidmüller.gois "all rights reserved": nothing taken from it). - EKD datasheets "AMPERE.Charge" (2023-04 and 2023-12).
- Research comment in #523.