OpenAmpere

For developers

This page is technical. It is meant for developers who want to connect OpenAmpere with their own app, dashboard or script. You don't need it for Home Assistant; the integration does this for you.

Interface for other apps

This page is for developers of other apps, such as dashboards, home automation or your own scripts, that want to read data from OpenAmpere or control it. The Home Assistant integration (custom_components/openampere/) uses exactly this interface and is the reference client: api.py and config_flow.py. The server side is external.py and apitokens.py (#76).

Apps that need only the power values of the former cloud can use the read-only endpoint /api/v1/installation/{id}/now/all/power of the web app instead. It needs no token, but it offers only five values.

Use OpenAmpere as the only Modbus client. Many inverters accept only one Modbus TCP connection, or very few (#311). An app that reads the inverter directly while OpenAmpere runs can take turns with OpenAmpere or lock it out. Read the values from this interface instead.

Overview

Connecting

There are two ways to get a token. Pairing is the better one for an app with a user interface: the owner does not copy a secret, only compares six digits.

Pairing

Pairing works like numeric comparison when pairing Bluetooth devices. Your app and OpenAmpere each compute six digits from the certificate the app sees and two random numbers. If someone sits in between, the app sees a different certificate and the digits differ.

  1. Ask the owner for the address and the HTTPS port. Prefer the IP address: a host name needs to be allowed in OpenAmpere first (see Errors).

  2. Read the certificate. Open a TLS connection without verification and compute the SHA-256 of the certificate in DER form (fingerprint, 64 hex characters). Keep it; from now on accept only this certificate.

  3. Commit to a random number. Create 32 random bytes app_nonce and send their SHA-256 as hex:

    POST /api/external/v1/pair/start
    {"name": "My dashboard", "commitment": "<sha256(app_nonce) as 64 hex characters>"}
    

    The answer contains request_id, poll_key (secret, keep it in memory), the server's random number nonce (32 bytes as hex), expires_in (600 s), api_version, installation_id and version. The name (at most 40 characters) is what the owner sees in OpenAmpere and in the control log.

  4. Reveal your number within 60 seconds:

    POST /api/external/v1/pair/{request_id}/reveal
    {"poll_key": "<poll_key>", "nonce": "<app_nonce as hex>"}
    

    Only now does the request appear in OpenAmpere, with its code.

  5. Show the code and ask the owner to compare it with the one in OpenAmpere (Mehr → Verbundene Apps):

    digest = sha256(bytes.fromhex(fingerprint) + app_nonce + bytes.fromhex(server_nonce)).digest()
    code = f"{int.from_bytes(digest[:4], 'big') % 1_000_000:06d}"
    
  6. Wait for the decision. Poll every 2 seconds:

    POST /api/external/v1/pair/{request_id}/status
    {"poll_key": "<poll_key>"}
    

    The answer is {"status": "pending"}, {"status": "rejected"} or {"status": "approved", "token": "oa_…", "scope": "read"}. The token is handed out once; store it together with address, port and fingerprint. 404 means the request expired (after 10 minutes) or OpenAmpere restarted: start again.

Limits against misuse: at most 3 open requests per device and 10 in total, at most 10 starts per device and 30 in total per hour. Beyond that pair/start answers 429. OpenAmpere keeps at most 10 tokens. With 10 already there, the owner cannot approve until they remove one; your app then sees pending until the request expires.

Connection code

Alternatively, the owner creates a token under Mehr → Verbundene Apps and copies the connection code. It is openampere1: followed by URL-safe Base64 (without padding) of this JSON:

{"host": "192.168.x.x", "port": 8443, "fingerprint": "<64 hex characters>", "token": "oa_…"}

The host is the address the owner's browser used; your app should let the owner change it. A host name instead of an IP address works only after the owner added it under Mehr → Zugriffsschutz → Eigene Adressen; otherwise every HTTP request gets 421.

Example client

Pairing and one reading in Python, with nothing but the standard library. A real app keeps the token and the fingerprint and skips the pairing next time; for live values it opens the WebSocket (/ws) with the same header and the same certificate check.

import hashlib
import http.client
import json
import secrets
import ssl
import time

HOST, PORT = "192.168.x.x", 8443  # ask the owner


def connect(fingerprint=None):
    context = ssl.create_default_context()
    context.check_hostname = False
    context.verify_mode = ssl.CERT_NONE  # instead: exactly this certificate, checked below
    conn = http.client.HTTPSConnection(HOST, PORT, context=context, timeout=20)
    conn.connect()
    seen = hashlib.sha256(conn.sock.getpeercert(binary_form=True)).hexdigest()
    if fingerprint and seen != fingerprint:
        conn.close()
        raise RuntimeError("OpenAmpere shows a different certificate: pair again")
    return conn, seen


def call(method, path, fingerprint, body=None, token=None):
    conn, _ = connect(fingerprint)
    headers = {"Content-Type": "application/json"}
    if token:
        headers["Authorization"] = f"Bearer {token}"
    conn.request(method, "/api/external/v1" + path, json.dumps(body) if body is not None else None, headers)
    response = conn.getresponse()
    data = json.loads(response.read() or b"{}")
    conn.close()
    if response.status >= 400:
        raise RuntimeError(f"{response.status}: {data.get('detail')}")
    return data


# pairing: once, then store HOST, PORT, fingerprint and token
_, fingerprint = connect()
app_nonce = secrets.token_bytes(32)
start = call("POST", "/pair/start", fingerprint,
             {"name": "My dashboard", "commitment": hashlib.sha256(app_nonce).hexdigest()})
request, poll = f"/pair/{start['request_id']}", {"poll_key": start["poll_key"]}
call("POST", request + "/reveal", fingerprint, {**poll, "nonce": app_nonce.hex()})
digest = hashlib.sha256(bytes.fromhex(fingerprint) + app_nonce + bytes.fromhex(start["nonce"])).digest()
print("Compare in OpenAmpere (Mehr → Verbundene Apps):", f"{int.from_bytes(digest[:4], 'big') % 1_000_000:06d}")
while (status := call("POST", request + "/status", fingerprint, poll))["status"] == "pending":
    time.sleep(2)
if status["status"] != "approved":
    raise SystemExit("The owner rejected the request.")
token = status["token"]

# reading
state = call("GET", "/state", fingerprint, token=token)
live = state["live"] or {}
print(f"PV {live.get('pv_power')} W, battery {live.get('battery_soc')} %, grid {live.get('grid_power')} W")

Reading

GET /info

What is connected. Read it once after connecting and again when status changes in a way that matters to you (for example a new PV inverter in pv_external).

{
  "api_version": 1, "version": "0.38.0", "installation_id": "…",
  "token": {"name": "My dashboard", "scope": "read"},
  "device": {"manufacturer": "FoxESS", "model": "H3", "firmware": "…", "rated_power_w": 10000,
             "supports_control": true, "work_modes": null, "backup_reserve": false},
  "pv_inputs": [{"index": 0, "name": "Süddach"}, {"index": 1, "name": "Modulfeld 2"}],
  "pv_input_count": 2,
  "pv_external": null,
  "devices": [{"id": "…", "name": "Heizstab", "kind": "mypv"}],
  "wallboxes": [{"id": "…", "name": "Garage", "model": "…", "read_only": false}],
  "poll_interval": 10, "web_port": 8080,
  "inverter_controls": []
}

GET /state

Everything at once: the same content as a live message, plus the settings.

{
  "type": "state",
  "live": { "…": "see below" },
  "status": { "…": "see below" },
  "devices": [],
  "wallboxes": [],
  "battery_settings": {"work_mode": "self_use", "min_soc": 10, "max_soc": 100, "min_soc_on_grid": 15,
                       "backup_soc": null},
  "grid_charging": {"enabled": false, "target_soc": 80, "active": false},
  "price_ct": 31.2
}

live: the latest reading

null before the first reading. All values can be null when the device does not provide them.

FieldMeaning
timestampTime of the reading
pv_powerSolar power, ≥ 0. Includes pv_external_power if the owner counts a second PV inverter.
pv_external_powerPower of a second PV inverter the device measures, ≥ 0
house_powerConsumption of the house, ≥ 0
grid_power+ import from the grid, − export to the grid
battery_power+ discharging, − charging
battery_soc, battery_sohState of charge and state of health in %
battery_voltage, battery_current, battery_temperatureBattery in V, A and °C
pv_inputsList per PV input: power, voltage, current. The position matches index in /info; also contains hidden inputs.
temperatures°C by name: inverter, ambient, battery, battery_cell_max, battery_cell_min, and the same with battery2 for a second battery. Only what the device provides.
inverter_stateThe device's own state number (meaning per device, see docs/devices/)
off_gridThe device reports off-grid operation in this reading. For a confirmed outage use status.off_grid.
alarmsThe device's alarm codes
todayEnergy since midnight in Wh, see below
totalsLifetime counters in Wh, see below
invertersEmpty with one inverter. With further inverters of the same installation (#619): one entry per inverter, the first with id "main", each with id, name, connected, has_pv and has_battery (whether it ever reported them; null while not known) and, while it answers, pv_power, pv_external_power, battery_power, battery_soc, grid_power and alarms; left_out: true for one that has been away for more than 5 minutes; in_first: true for one whose values the first inverter already reports (a parallel system), which is shown but not part of the combined values. The fields above are then the combined values: PV and battery added up, the grid from the first inverter (plus those that measure a grid connection of their own), the house from the balance, the state of charge weighted by battery size; pv_inputs holds the inputs of all inverters, each inverter always at the same positions (empty while it has no reading). While a further inverter has had no reading for up to 5 minutes, the combined PV, battery, house, state of charge and the summed counters in totals and today are null (the gap is spread later). After that it is left out (left_out): the combined values and counters come back without it, so a lower sum then means an inverter is missing, not less power. Its counters count again from its next reading; what it produced while away is not in totals. Battery and temperature details are the first inverter's.

Fields of today and totals: pv, consumption (what the app shows as consumption), grid_import, grid_export, battery_charge, battery_discharge, load (the inverter's own load counter, which can count much more than the house used; prefer consumption) and, only in totals, pv_external.

status

FieldMeaning
connectedOpenAmpere is connected to the inverter
staleNo new reading for more than 60 seconds: show the values as outdated
last_updateTime of the latest reading
off_gridA power outage OpenAmpere has confirmed
grid_chargingGrid charging is running right now
control{"enabled", "dry_run"}: the master switch for control and the test mode
firmwareFirmware of the inverter (changes with an update)
token_days_leftDays until the token of an Enphase gateway runs out, null for other devices
pv_externalAs in /info

devices and wallboxes

devices (heaters and relays OpenAmpere switches): id, name, kind, enabled, power_w, on, temperature_c, target_c, status, error and mode (auto, off or boost).

wallboxes (wallboxes OpenAmpere reads itself): id, name, enabled, mode, max_current_a (the owner's limit), mode_current_a (highest current per charging mode), and the live values online, state, connected, charging, power_w, current_a. The live values are null while the wallbox does not answer, which is normal for a portable one that is unplugged.

Live values: /ws

A WebSocket at wss://<host>:<port>/api/external/v1/ws with the same Authorization header. Right after connecting and after every new reading of the inverter (every poll_interval seconds) OpenAmpere sends:

{"type": "live", "live": {}, "status": {}, "devices": [], "wallboxes": []}

The settings (battery_settings, grid_charging, price_ct) are not part of it; read /state after a command or every few minutes. A connection without a valid token or over plain ws:// is refused in the handshake with HTTP 403. An open connection whose token the owner removes is closed with code 1008. Reconnect with a growing pause (the integration waits 5, 10, 30, then 60 seconds). OpenAmpere shows which apps are connected live.

History

The history a read token may see, with the same answers as the charts in the web app (#588). All of them are GET requests with query parameters; times in the answers are the start of each bucket.

Parameters shared by several endpoints:

An unknown period or a date that cannot be read answers 400; a parameter outside its values (step, resolution, mode) answers 422 with FastAPI's technical list (see Errors).

At most 30 reads of the history per minute and token, for all five endpoints together. Beyond that the answer is 429, with the seconds to wait in the message. Live values (/state, /ws) do not count.

What is kept: energy per quarter hour is kept for good, so summary, energy and the energy of pv-inputs work for any period OpenAmpere has recorded (or imported from the former cloud). The single readings behind power, the power curve of pv-inputs and temperatures are kept for 30 days by default (the owner can change that); older days answer with empty entries, except power, which then has the average of each quarter hour (see there).

GET /history/summary

Energy of a period, the shares and the money, as the report in the app shows them.

GET /api/external/v1/history/summary?period=month&date=2026-06
{
  "period": "month", "from": 1780264800, "to": 1782856800, "quarters": 2880,
  "partial_since": null, "recorded_since": null,
  "energy_wh": {"pv": 1200000, "load": 900000, "grid_import": 150000, "grid_export": 450000,
                "battery_charge": 200000, "battery_discharge": 180000, "pv_external": null},
  "autarky": 0.83, "self_consumption": 0.63,
  "money": {"savings_eur": 210.5, "feed_in_eur": 36.0, "grid_cost_eur": 45.3, "base_fee_eur": 12.0,
            "net_cost_eur": 21.3, "incomplete": false}
}

GET /history/energy

Energy per bucket, for bar charts. Parameters: period, date, resolution (default 15m).

{"period": "day", "resolution": "60m", "from": 1780351200, "to": 1780437600,
 "entries": [{"ts": 1780351200, "pv": 0, "load": 350, "grid_import": 350, "grid_export": 0,
              "battery_charge": 0, "battery_discharge": 0, "pv_external": null, "soc": 42}]}

Each entry has the energy of the bucket in Wh (fields as in summary) and soc, the state of charge at the end of the bucket. A bucket without data is missing, not zero. The quarter hour that is running is included.

GET /history/power

Power curve of one day. Parameters: date, step (seconds per point, 10–3600, default 60).

{"from": 1780351200, "to": 1780437600, "step": 300,
 "entries": [{"ts": 1780394400, "pv": 4200, "house": 600, "grid": -2100, "battery": -1500, "soc": 64,
              "pv_external": null}]}

Averages per step in W, with the signs of live: grid + import, − export; battery + discharging, − charging. A step without readings is missing. A quarter hour with no readings but with stored energy or state of charge (a day imported from the former cloud, or older than the readings are kept) has one entry at its start with "quarter": true: the average power of that quarter hour from its energy (Wh × 4) and its state of charge. Values the quarter hour has no energy for are null. A gap in OpenAmpere's own readings (it did not run) stays missing, also once the readings around it are no longer kept.

GET /history/pv-inputs

Per PV input (module array). Parameters: period, date, mode (energy, default, or power, only with period=day), resolution (default 60m, for energy).

{"mode": "energy", "inputs": [1, 2], "labels": ["Süddach", "Modulfeld 2"],
 "entries": [{"ts": 1780394400, "values": [2100, 1400]}], "totals_wh": [21000, 14000]}

GET /history/temperatures

Temperatures of one day. Parameters: date, step (seconds, 60–3600, default 300).

{"entries": [{"ts": 1780394400, "inverter": 41.5, "battery": 24.0, "cell_max": 24.5, "cell_min": 23.5}]}

Averages per step in °C, null for what the device does not provide.

Controlling

Commands need a control token, and the owner must have switched control on in OpenAmpere (Mehr → Steuerung und Protokoll). Everything goes through the same checks as in the app:

PUT /battery

Battery settings. Send only what you want to change.

{"work_mode": "self_use", "min_soc": 10, "max_soc": 100, "min_soc_on_grid": 20}
FieldValues
work_modeself_use, feed_in_first, backup, peak_shaving; only those in device.work_modes if that is not null
min_socLowest state of charge during a power outage (off-grid), 0–100 %
min_soc_on_gridBackup reserve, 10–100 %, at least min_soc
max_socCharge limit, 10–100 %, above min_soc_on_grid
backup_socReserve in the backup mode, 10–100 %, only if device.backup_reserve; not above max_soc

The answer is {"dry_run", "written", "warning"}. A backup reserve below 10 % can only be set in OpenAmpere itself, after a warning (428).

At most 6 changes per hour per setting. These settings end up in the inverter's permanent memory, and an automation stuck in a loop must not wear it out. Beyond that the answer is 429, with the minutes to wait in the message. A command refused before anything was written does not count.

Not every inverter accepts every command: supports_control in /info says whether OpenAmpere may control the device at all.

With more than one inverter (#619) PUT /battery?inverter=<id> changes the battery of a further one (the ids and what each offers are in inverter_controls of /info, its settings in inverter_battery_settings of /state); without inverter it changes the first one. The limit of 6 changes per hour counts per inverter. PUT /grid-charging switches grid charging of all batteries together.

PUT /grid-charging

Charging the battery from the grid, for example when electricity is cheap.

{"enabled": true, "target_soc": 80}

target_soc: 20–100 %. The owner must have set up grid charging once in OpenAmpere (it asks about the legal side); until then switching it on answers 400. OpenAmpere charges through the inverter's remote control with a watchdog, so charging stops by itself when OpenAmpere stops. Answer: {"enabled", "target_soc", "active"}. At most 60 changes per hour.

PUT /devices/{id}/mode

Mode of a heater or relay from devices:

{"mode": "boost", "hours": 2}

mode: auto (follow the solar surplus), off (stay off) or boost (full power, for example hot water now). hours (optional, up to 48) ends off or boost after that time; without it the mode stays until changed. Answer: {"devices": [...]}. At most 60 changes per hour per device.

PUT /wallboxes/{id}/mode

Charging mode of a wallbox OpenAmpere controls itself (not read_only):

{"mode": "pv", "current_a": 16}

mode: off, pv (solar surplus only), minpv (minimum current plus surplus), now (full current) or manual (OpenAmpere leaves the wallbox alone; the owner controls it on the wallbox itself). current_a (optional, only with pv, minpv and now) sets the highest current of that mode, within the owner's limit. Answer: {"wallboxes": [...]}. At most 60 changes per hour per wallbox.

Errors

Errors are JSON with a German explanation for the owner in detail, which your app can show as it is (except for 422, see below):

{"detail": "Dieser Zugang darf nur lesen.", "code": "read_only"}
StatusMeaning
400Invalid value or command; detail says what is wrong
401Token invalid or removed ("code": "token_invalid"): pair again
421An HTTP request used a host name that OpenAmpere does not know (protection against DNS rebinding); no code field. Use the IP address, or the owner adds the name under Mehr → Zugriffsschutz → Eigene Adressen.
403Plain HTTP (https_required), a read token tried to write (read_only), or control is switched off in OpenAmpere
404Pairing request expired or unknown
422The body is not a JSON object (an array, a number, broken JSON or no body), or a query parameter of the history is outside its values. Here detail is FastAPI's technical list in English, not a text for the owner: a bug in your app.
428Needs a confirmation that only OpenAmpere itself can ask for
429Too many changes, pairing requests or reads of the history; detail says how long to wait
502The inverter refused the write or did not confirm it
503OpenAmpere is not connected to the inverter

A changed certificate shows up as a failed TLS handshake (the fingerprint does not match). Do not accept the new certificate silently: ask the owner to pair again.

Good manners