These pages are technical. They collect what the OpenAmpere contributors have found out about the devices, each fact with its source and how sure it is. They show the latest state of development, which can be ahead of the version you have installed. They are not official manufacturer information. You don't need them to set up OpenAmpere; the app explains everything you need.

RCT Power Storage DC, Storage AC and Power Inverter

Not official manufacturer information: compiled by the OpenAmpere contributors, can be incomplete or wrong. No affiliation with RCT Power GmbH, its insolvency administrator or EKD; not legal advice. See the device knowledge README.

Applies to: RCT Power Storage DC (4.0 to 12.0, also the "LAN" variants), Power Storage AC and Power Inverter with the RCT app's local protocol · Sold as: RCT Power systems through installers · OpenAmpere: driver rct (src/openampere/drivers/rct/), "register map" rct_serial · Support and confirmation: kept in support.json

Summary

The insolvency

FactStatusSource
Insolvency proceedings for RCT Power GmbH, Konstanz (commercial register Freiburg im Breisgau, HRB 713720): Amtsgericht Konstanz, file number K 42 IN 457/26, published 2026-09-15.documentedinsolvenzbekanntmachungen.de (court: Konstanz, enter the file number)
A provisional insolvency administrator was appointed on 2026-09-14; the search for an investor began. Installed systems keep running; service, warranty, app and portal are open.documentedpv magazine, 2026-09-16; Photon, 2026-09-23
Battery errors such as "BAT_INTERN Error Class 3" could so far only be reset by RCT's service through a remote connection. OpenAmpere does not do this and writes nothing to the battery management.derivedowners' reports in the Photovoltaikforum, 2026-10

Models

ModelVariantsPeriod (about)BatteryNetworkStatusSource
Power Storage DC, first generation4.0, 5.0, 6.0 (3-phase)2016–2019yes (Power Battery, high voltage)WLAN; early units without a LAN portdocumentedRCT datasheet "Power Storage DC" (04/2018); RCT Power Portal manual (LAN port from certain serial numbers on)
Power Storage DC4.0, 6.0, 8.0, 10.0 (3-phase; 8.0 and 10.0 with two battery towers)about 2019–2026yesWLAN and LANdocumentedRCT datasheets and manuals (download area of rct-power.com)
Power Storage DC LAN6.0, 8.0, 10.02025–2026yesLAN only, no WLANdocumentedRCT datasheet "Power Storage 6–12" (2507)
Power Storage DC 12.012.0announced 2026yesLANdocumented (announced)RCT datasheet "Power Storage 6–12" (2507)
Power Storage AC6.0 (older sizes unknown)about 2017–2026yes (AC-coupled, no PV inputs)WLAN and LANdocumentedRCT compatibility matrix TD25 (02-2024)
Power Inverter4.0, 6.0 (5.0 in certificates)about 2016–2026noWLAN and LANdocumentedRCT compatibility matrix TD25 (02-2024)
Power Storage DC 6.0 SP6.0, single-phaseshown 2024yesunknownopen: whether it speaks the same protocoltrade fair report (TaiyangNews, 2024)
Power Storage Flex15.0 to 29.92025–2026yes (Power Battery Flex)WLAN/LAN/4G stick, its own monitoring platformopen: probably another platform with its own interfaceRCT manual "Power Storage Flex" (26V1)

The app, the portal and the master–slave plants cover Storage DC, Storage AC and Power Inverter alike (compatibility matrix TD25). Power Battery, Power Switch (backup box) and Power Sensor (current transformers) are accessories without a network interface of their own; the inverter reports their values.

Protocol

RCT Power's "Serial Communication Protocol", document version 1.14 (2022-02-11). It is not in RCT's public download area; owners and integrators got it from RCT on request. Facts in own words, see the README.

FactStatusSource
TCP, default port 8899; the same protocol as the WLAN board uses with the app.documentedRCT protocol 1.14
Port 502 (Modbus TCP) is closed on these inverters; Modbus RTU only on the RS485 terminal (9600 baud).derivedowners' reports in the Photovoltaikforum ("RCT Power DC 10.0 – Anbindung per Modbus TCP"); RCT "RS485 Communication with external devices" v1.2 (2020-04-29)
Frame: start byte + (0x2B), command, length (2 bytes for the long commands), object id (4 bytes), data, CRC-16. Big endian; floats IEEE 754 single precision. One zero byte may come before a frame.documentedRCT protocol 1.14
CRC-16/CCITT, polynomial 0x1021, start 0xFFFF, over command, length, id and data; padded with one zero byte to an even length.documentedRCT protocol 1.14 (with two example frames, OpenAmpere's tests check both)
+ and - (0x2D) inside a frame are sent as - followed by the byte; the escape is not part of the CRC.documentedRCT protocol 1.14
Commands: 0x01 read, 0x02 write, 0x03 long write, 0x05 response, 0x06 long response (texts, arrays, values over 251 bytes), 0x08 read periodically. Plus 0x40: the same for a further device of a plant, with its 4-byte address.documentedRCT protocol 1.14
An object the device does not know gets no answer.derivedpython-rctclient documentation (behaviour only, no code)

Values

Objects as RCT's document names them; "Registers" here are 4-byte object ids. All read only.

Object idNameMeaningType, unit, signStatusSource
0x7924ABD9inverter_snSerial numbertextdocumentedRCT protocol 1.14
0xDDD1C2D0svnversionControl software versiontextdocumentedRCT protocol 1.14
0xB5317B78, 0xAA9AA253dc_conv.dc_conv_struct[0/1].p_dcPower of solar generator A and Bfloat, WdocumentedRCT protocol 1.14
0xB298395D, 0x5BB8075Adc_conv.dc_conv_struct[0/1].u_sg_lpVoltage of solar generator A and Bfloat, VdocumentedRCT protocol 1.14
0x1AC87AA0g_sync.p_ac_load_sum_lpHousehold load ("load household minus external power")float, Wdocumented; with an S0 meter openRCT protocol 1.14
0x91617C58g_sync.p_ac_grid_sum_lpTotal grid power, + = importfloat, Wdocumented (meaning); derived (sign)RCT protocol 1.14; evcc rct-power meter (MIT)
0x400F015Bg_sync.p_acc_lpBattery power, + = dischargingfloat, WdocumentedRCT protocol 1.14
0x4E49AEC5g_sync.p_ac_sumReal power of the inverterfloat, WdocumentedRCT protocol 1.14
0x959930BFbattery.socState of chargefloat, 0 to 1documented (meaning); derived (range)RCT protocol 1.14; evcc rct-power meter
0x381B8BF9battery.sohState of healthfloat, 0 to 1documented (meaning); derived (range)RCT protocol 1.14
0x65EED11B, 0x21961B58battery.voltage, battery.currentBattery voltage and currentfloat, V, A; sign of the current opendocumentedRCT protocol 1.14
0x902AFAFBbattery.temperatureBattery temperaturefloat, °CdocumentedRCT protocol 1.14
0xF79D41D9db.temp1Heat sink temperaturefloat, °CdocumentedRCT protocol 1.14
0x5F33284Eprim_sm.stateInverter state (enumeration, meanings not known)uint8documentedRCT protocol 1.14
0xFC724A9E, 0x68EEFD3Denergy.e_dc_total[0/1]Lifetime energy of solar generator A and Bfloat, WhdocumentedRCT protocol 1.14
0x62FBE7DC, 0x44D4C533energy.e_grid_load_total, energy.e_grid_feed_totalLifetime energy from and to the gridfloat, WhdocumentedRCT protocol 1.14
0xEFF4B537energy.e_load_totalLifetime household energyfloat, WhdocumentedRCT protocol 1.14
0x5570401B, 0xA9033880battery.stored_energy, battery.used_energyLifetime energy into and out of the batteryfloat, WhdocumentedRCT protocol 1.14
0xCE266F0F, 0x97997C93power_mng.soc_min, power_mng.soc_maxThe owner's lower and upper state of charge targetsfloat, 0 to 1documentedRCT protocol 1.14
0xE96F1844io_board.s0_external_powerA further PV inverter on the S0 inputfloat, Wdocumented; not read yetRCT protocol 1.14

Decisions in OpenAmpere

DecisionWhyIssue/PR
Every write method refuses, supports_control is off.Whether the inverter has a remote control with a watchdog timeout (needed for any continuous control) is open.#646
Only when the owner chooses "RCT Power"; port 502 stands for 8899. Its error messages name the RCT inverter, not Modbus.It does not answer on the Modbus port.#646
One TCP connection, kept open; all objects of a read are requested at once, the answers collected for up to 2 s. An object without answer stays empty; if nothing answers, the read failed and the connection is opened again.Like the app; a device without battery or with older firmware may not know every object.#646
On every new connection the serial number is read first and compared with the owner's inverter. If the owner's inverter stays silent (e.g. while its network board restarts), that is a failed read, not "no RCT inverter at this address".Nothing is read from another device at the same address (#567).#646
Plant frames (further devices behind the master) are ignored.One driver reads one inverter.#646
The S0 input (a further PV inverter) is not read yet.How it adds up with the household load needs a device with one.#646
The diagnostics show the objects of the last read with RCT's own signs and units (powers rounded) and which did not answer; not the serial number and no counters. No extra request.So the first owner's report can confirm the signs.#646
No search for a new address when the device is unreachable, and the device query (Mehr → Geräteabfrage) does not read it: it says so.Both read Modbus registers only. A fixed IP address in the router keeps it reachable.#646
No GPL or LGPL code or tables: the object ids come from RCT's document.Projects whose license does not allow reuse are not a source (README).#646

Open questions